Logs are a key part of any troubleshooting process. Having the ability to view a history of major switch events from a centralized Syslog server can greatly accelerate the troubleshooting process when multiple network devices are involved.
The FLEX24-10G supports linking the switch with an external Syslog server. Once the switch has been configured to utilize a Syslog server and a connection has been established, all system logs will be sent to the server.
FLEX24-10G# configure terminal
FLEX24-10G(config)# logging on
FLEX24-10G(config)# logging host 192.168.100.50
FLEX24-10G(config)# logging level warning
FLEX24-10G(config)# end
FLEX24-10G# copy running-config startup-config
Building configuration...
% Saving 2381 bytes to flash:startup-config
FLEX24-10G#
Refer to the Video tutorial to know more about enabling Syslog services on the switch.
Refer to the Admin Guide for all the advanced settings available in the switch. You’ll find additional resources like the Datasheet, Admin Guide, A&E spec sheet, etc on the product page here.